Flow Water
As all pump operators should know, water should always be flowing to prevent the pump from overheating.
When discharge lines are not being used, you should recirculate water through the pump by opening the "Tank Suction" valve and the "Tank Fill" valves.
When you need more water pressure, you can increase the throttle and close the "Tank Fill" valve all or part way.
There are two discharge lines marked "1.5 Discharge" (preconnect hose on the left rear) and "Booster Reel" (hose reel on left front).
There are also grass nozzles which are explained on the next page.
There is one inlet line on the right which is marked "2.5 Inlet"
Valve Lavel Function
1.5 Discharge Attack line located on left rear
Grass Nozzles Attack spray nozzles on front of vehicle
Booster Reel Attack hose reel located on left front
Tank Fill Pump to tank valve
Tank Suction Tank to pump valve
2.5 Inlet Inlet valve to fill tank
Action Valve Positions
Idle Open Tank Suction and Tank Fill; all others closed
Attack fire Open Tank Suction, crack Tank Fill, open one of three attack line valves
Fill tank Open Tank Fill and 2.5 Inlet, all others closed